Installation Frame for 2 Bard and Brazier Floating Rail
Product no.: INF2-2
Description
Installation Frame for 2 Bard and Brazier Floating Heated Towel Rails
Either a D-Rail, La Fayette or a Zingo Sultan
This frame is for two rails only
This frame has to be fixed to a concealing wall panel of some sort
You then connect the the central heating to this for the water supply
Gap between the rails is 160mm and the gap to the valve from the bottom rail on the La Fayette and Zingo ranges is 180mm
The D-Rail frame does not need any concealed valves (as per the picture),
because each D-Rail has an intergrated valve and can also be turned on and off on the rail itself
If used for a La Fayette or Zingo Sultan Rail then you need to use 2 of either a Panama or a Pullman concealed valve
Which are available to buy below in accessories
This is what the Bard and Brazier head engineer said about the depth this need to be fitted at:
"The copper pipe connections must protrude 27mm – 28mm from the finished wall surface.
Therefore the maximum wall cavity depth is 151mm. If they have a shallower wall cavity,
they need to trim the copper pipes after they have applied the finished wall surface to said 27 – 28mm dimension (installation instruction)"